Q-See QT17DVR4C User Manual

Page 12

Advertising
background image

-e10-

LCD WITH BUILT-IN DVR USER MANUAL

LCD WITH BUILT-IN DVR USER MANUAL

-e13-

a).

If it has a X symbol in front of the channel number code,

Note:

it means the

can't record video. However, you can still see the

image under monitoring if the channel has image signal. But, the system will not prompt

the alarm message if the image signal of this TV screen has lost.

b).

: Name of the

Move the

to this topic

and press enter and

When you have finished, press enter.

c). Screen Display: Two choices are switch on or switch off. If

, it will show the

channel title

monitoring. If selecting

off, it will not show channel title

monitoring.

d). Time Insert: There are three choices for users, up, down or close. Press Enter to make your selection.

When option up is selected, the time will be displayed on top of the screen, when option Down is
selected, the time will be displayed at the bottom of the screen. If the option Closed is selected,
the time will not be displayed on the screen.

e).

Two choices for users are switch on or switch off. You can press enter for any changes.

TV

for covering the

f).

Two choices for users are open or close.

Channel: Enter the channel number.
it indicates invalid channel.

For each channel,

channel

channel

Title

channel. Enter the title of the camera location.

cursor

enter the channel title.

switch on is selected

while

switch

while

Mask:

mask used

part of channel which is not to be recorded.

Channel View:

Open keeps the channel open for viewing

and close blocks the image from viewing.

3.3.3 Alarm Setting

a).

1, 2, 3,

b).

C).

Two choices are(close/short)closed circuit and open circuit.

d).

Terminal:

Open:

inputting way:

4 respectively represent 4 outer I/O alarm input ports.

Two choices are open or close. Open indicates the system has received the input alarm signals

from the I/O end points. Close indicates the system has not received the input alarm signals.

Users have the

option to turn on /off alarm for each channel

Under the alarm recording condition, the system receives the alarm signal

from I/O. The system recording video is according to the time length which the user has already
set up. The system will stop recording video automatically when it has reached the end of its set time
since it has not received the alarm signal from the new I/O.

Delay alarm recording:

3.2 System on/off
3.2.1 System Start

When supplying power to DVR normally, the system enters into stand-by state(the indicating
light of the power-red led is on permanently)。
When press the【on/off】button in the remote control unit,the system is started,pictures
displayed in the screen are built-in quad images,the digit showed in each picture means its video
input channel No. the real time will be displayed at the top

of the screen.

the remote control unit or panel,

Note:

has been setup in this machine(or at high peak period),

and power is just connected during this period, then the machine will start and enter
into multi-pictures state directly without needing to press【on/off】button again to start
the machine.
If there

no display of video input channel No in the screen and the real time for the

system, please press【ENTER】 button

center

If time recording

is

on

and the channel

numbers will be displayed on the screen
If the hard disc has not been installed before turning on the machine, or the hard disc is not
detected by the machine after turning it on, the monitor with hard disc will set off the alarm,
Please log in the system to turn off the alarm.

3.2.2 System Login

Note:

【Login/Lock】

Note:

re-delivery code for this equipment is:000,the default password for

administrator is 88888888,and it is 00000000 for user. Administrator
has all

operating rights. In order to make sure the safe running of the

system, administrators should change its code and default password of the
machine

When the host machine is started,user can only operate the system when

When the machine is just started or under lock up state, press the

Button on

Remote Control Unit,the login interface in the screen will appear, type in the code of the

machine(Pre-delivery setup: 000 ),and then type in the password(password for

administrator or operator of this machine).
⑴ If correct user's password is typed in,the monitor will show Password Correct message on

the screen, and then after [Return] for confirmation,users can operate each items within

the permitted field(the default password for user is:00000000).

⑵ If correct administrator's password is typed in,

will show Password Correct

the screen,and then after [Return] for confirmation,administrator can

the operations in the machine(The default password for administrator is:88888888)。

the monitor

message on

There are two password management- one for administrator and another for user,

different operating range will be permitted by inputting different password.

P

immediately.

logged in

perform

all

the

If there is

no activity within 100 seconds after logging in, the system will enter into lock state!

.

''

''

''

''

''

''

Channel setup

channel

setting includes

name, screen display, clock insert,

TV screen cover, etc

3.3.2 CHANNEL SETUP

Channel Setup

CH

Title

CH Name

Time InSert

Mask

CH View

1

Open

Down

Close

Open

2
3
4

Return

Open

Down

Close

Open

Open

Down

Close

Open

Open

Down

Close

Open

PDF created with pdfFactory trial version

www.pdffactory.com

Advertising