Desa international unvented natural gas log heater, Troubleshooting, Continued – Desa B User Manual

Page 20

Advertising
background image

20

104414

DESA INTERNATIONAL
UNVENTED NATURAL GAS LOG HEATER

OBSERVED PROBLEM

One or both burners do not light after ODS/
pilot is lit

Delayed ignition of one or both burners

Burner backfiring during combustion

Yellow flame in front burner during burner
combustion

Slight smoke or odor during initial operation

Heater produces a whistling noise when
burners are lit

Moisture/condensation noticed on windows

White powder residue forming within burner
box or on adjacent walls or furniture

REMEDY

1. Contact local natural gas company
2. Clean burner(s) (see Cleaning and Main-

tenance, page 18) or replace burner
orifice(s)

3. Contact qualified service person
4. Replace burner orifice(s)

1. Contact local natural gas company
2. Clean burner(s) (see Cleaning and Main-

tenance, page 18) or replace burner
orifice(s)

3. Contact qualified service person

1. Clean burner (see Cleaning and Main-

tenance, page 18) or replace burner
orifice

2. Replace damaged burner
3. Replace gas regulator

1. Check burner(s) for dirt and debris. If

found, clean burner(s) (see Cleaning and
Maintenance
, page 18)

2. Replace gas regulator

1. Problem will stop after a few hours of

operation

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burners until air is removed

from line. Have gas line checked by lo-
cal natural gas company

3. Observe minimum installation clear-

ances (see pages 7 through 9)

4. Clean burners (see Cleaning and Main-

tenance, page 18) or replace burner
orifice(s)

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn heater off when using furniture

polish, wax, carpet cleaners, or similar
products

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Inlet gas pressure is too low
2. Burner orifice(s) clogged

3. Mislocated crossover tube
4. Burner orifice(s) diameter is too small

1. Manifold pressure is too low
2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

1. Residues from manufacturing processes

and logs curing

1. Turning control knob to HI position

when burners are cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner

orifice(s)

1. Not enough combustion/ventilation air

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue

www.desatech.com

Advertising
This manual is related to the following products:

C