Db_e13-14, Rouble shooting the system, Pecifications – DB Drive Speed Series Amplifier SPA SPA90.2 User Manual

Page 8

Advertising
background image

13

14

T

ROUBLE SHOOTING THE SYSTEM

We have put together this trouble-shooting guide if you experience problems after

installing the amplifier. Please keep in mind that the majority of problems incurred are

caused by improper installation and not the equipment itself. In addition, there are many

components in the system that could cause various signal problems such as inducted

electrical noise and engine noise.

Before you can properly address the problem, you must first find the component that is

causing the problem. This will take patience and a process of elimination.

LOOK FOR…..

SOLUTION

No Output

Blown fuse

Replace

Bad RCA Cable(s)

Replace

+12V at power terminal

Check connection

+12V at remote terminal

Check connection

Grounding point clean and tight

Check for ground w/meter

Head Unit’s fader not in center position

Set to center position

Master & Slave settings

Confirm correct setting

Low Output

Check level adjustments

Re-adjust

Bad RCA cable(s)

Replace

Improper level matching

Re-adjust

Master & Slave settings

Confirm correct setting

Engine Noise

Grounding points are clean and tight

Check for ground w/meter

Ground all components at same point

Ground at same point

Try different grounding point

Change for better ground

Bad RCA cable(s)

Replace

Use High Quality shielded RCA cables

Rejects inducted noise

Low Vehicle charging system and/or battery Fix and/or replace

Red Protection L.E.D. illuminated

Speaker short

Check speakers connection

for short circuit

Speaker grounding out

Make sure speaker wires

Do not touch chassis ground

Impedance too low

Check speaker impedance

Overheating

Check mounting location

for Adequate air circulation

speaker impedance too low

S

PECIFICATIONS

Input Voltage @ 11 - 14.4 VDC:

@ 4 ohm

@ 4 ohms Bridged

@ 2 ohm

Frequency Resp.

S/N Ratio (A-weight)

Low Input Level

Crossover Type

Crossover Freq. (Lowpass)

Crossover Slope

Bass EQ.

Fuse Rating

Remote Bass

SPA90.2

2 x 90W

1 x 350W

2 x 175W

10Hz-20Khz

>90dB

200mV. - 5.8 V

Hi/Low Pass

55Hz - 400Hz

12db per oct

18dB @ 45Hz

2 x 20 amp

no

SPA1000D

1 x 250W

1 x 500W

1 x 1000W

20Hz - 250Hz

>90dB

246mV - 5.9V

Low Pass

40Hz - 150Hz

18dB/oct

18dB @ 45Hz

20Hz - 50Hz

Yes

2 x 20 amp

included

Input Voltage @ 11 - 14.4 VDC:

@ 4 ohm

@ 2 ohm

@ 1 ohm

Frequency Resp.

S/N Ratio (A-weight)

Low Input Level

Crossover Type

Crossover Freq. (Lowpass)

Crossover Slope

Bass EQ.

Subsonic Filter

Remote Control Included

Fuse Rating

Remote Bass

Input Voltage @ 11 - 14.4 VDC:

@ 4 ohm

@ 2 ohm

@ 1 ohm

Frequency Resp.

S/N Ratio (A-weight)

Low Input Level

Crossover Type

Crossover Freq. (Lowpass)

Crossover Slope

Bass EQ.

Subsonic Filter

Remote Control Included

Fuse Rating

Remote Bass

SPA1300D

1 x 325W

1 x 650W

1 x 1300W

20Hz - 250Hz

>90dB

246mV - 5.9V

Low Pass

40Hz - 150Hz

18dB/oct

18dB @ 45Hz

20Hz - 50Hz

Yes

2 x 25 amp

included

SPA1600D

1 x 400W

1 x 800W

1 1600W

20Hz - 250Hz

>90dB

246mV - 5.9V

Low Pass

40Hz - 150Hz

18db/oct

18dB @ 45Hz

20Hz - 50Hz

Yes

2 x 30 amp

included

SPA1900D

1 x 475W

1 x 950W

1 x 1900W

20Hz - 250Hz

>90dB

246mV - 5.9V

Low Pass

40Hz - 150Hz

18dB/oct

18dB @ 45Hz

20Hz - 50Hz

Yes

3 x 30 amp

included

SPA90.4

4 x 90W

2 x 350W

4 x 175W

10Hz-20Khz

>90dB

200mV. - 5.8 V

Hi/Low Pass

55Hz - 400Hz

12db per oct

18dB @ 45Hz

2 x 25 amp

optional