AR-B1565/1565A User’s Guide

24

17

–DTR2F 18

–RI2F

19

VCOM2 20

GND

21

–DCD3F 22

–DSR3F

23

RXD3F 24

–RTS3F

25

TXD3F 26

–CTS3F

27

–DTR3F 28

–RI3F

29

VCOM3 30

GND

31

–DCD4F 32

–DSR4F

33

RXD4F 34

–RTS4F

35

TXD4F 36

–CTS4F

37

–DTR4F 38

–RI4F

39

VCOM4 40

GND

(1) RS-232/RS-485 Select for COM3 (J6 & J8)

The J6&J8 jumper is used to choose between the use of the on-board RS-232 or RS-485 for the COM3.

J6

1

3

5

1

2

3

J8

RS-232

Factory Preset

J6

1

3

5

1

2

3

J8

RS-485

Figure 3-10 J6 & J8: RS-232/RS-485 Select for COM3

(2) RS-485 Terminator Select (J7)
When there is only one line the setting should be left off, but if you are using multiple blocks on a single line
this should be set to “ON” in order to properly terminate the connection for better transmission of data

OFF

Factory Preset

1
2

1

2

ON

Figure 0-5 J7: RS-485 Terminator Select

(3) RS-485 Header (J8)

1 2 3

1 N485+
2 N485-
3 GND

Advertising