Acrosser AR-V5430FLAT User Manual
Page 34
 
AR-V5430FL Installation Guide
11 TIMEMARK
1PPS
Time
Mark
Output
Output
12 GND
Ground
Interface Description
* VDC (DC power input): 
This is the main DC supply for a 3.8V ~ 5.5V power module board. 
 
* VBAT (Backup battery): 
This is the battery backup input that powers the SRAM and RTC when the main power is 
removed. The typical current draw is 10uA. Without an external backup battery, the 
module/engine board will execute a cold start after every start. To achieve the faster 
start-up offered by a hot or warm start, a battery backup must be connected. To 
maximize battery lifetime, the battery voltage should be between 2.5V and 3.6V. 
 
* PBRES (Push button reset): 
This pin provides an active-low reset input to the engine board. It causes the engine 
board to reset and start searching for satellites. 
 
* SELECT: 
Do not connect. 
 
* TXA: 
This is the main transmits channel for outputting navigation and measurement data to 
the user’s navigation software or user written software. 
Output RS-232 level 
 
* RXA: 
Normally this pin must be kept in high, and if you don’t use this pin please connect a 
resistor to pull high. 
 
* Time mark: 
This pin provides one pulse-per-second output from the engine board that is 
synchronized with the GPS time. 
 
* GND: 
GND provides the ground for the engine board. Connect all grounds. 