Technical service, Replacement parts, Service hints – Desa SVYD18N User Manual

Page 32: Specifications, Wiring diagram

Advertising
background image

111162-01A

32

For more information, visit www.desatech.com

For more information, visit www.desatech.com

TECHNICAL SERVICE

You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA Heating Products’ Technical
Service Department at 1-866-672-6040. When calling, please have
your model and serial numbers of your heater ready.

You can also visit DESA Heating Products’ technical services web
site at

www.desatech.com

.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This will protect your

warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply
original replacement part(s), call DESA Heating Products’ Techni-
cal Service Department at 1-866-672-6040. When calling DESA
Heating Products, have ready

• your name and address

• model and serial numbers of your heater

• how heater was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original
replacement part(s), call DESA Heating Products at 1-866-672-6040 for
referral information. When calling DESA Heating Products, have ready

• model number of your heater

• the replacement part number

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low (propane/LP only)

You may feel your gas pressure is too low. If so, contact your local
propane/LP or natural gas supplier.

SPECIFICATIONS
WIRING DIAGRAM
REPLACEMENT PARTS
SERVICE HINTS
TECHNICAL SERVICE

SPECIFICATIONS

(F)SVYD18P(R)

(F)SVYD18N(R)

Btu (Variable)

16,000/30,000

16,000/30,000

Type Gas

Propane/LP Only

Natural Only

Ignition

Piezo

Piezo

Pressure Manifold

8" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

10.5"

Minimum*

11"

5"

Shipping Weight

28 lbs.

28 lbs.

* For input adjustment

WIRING DIAGRAM

(SVYD18PR and FSVYD18PR Series Remote-
Ready Models Only)

Note

: For proper operation of optional accessories, the wires from

the switch to the control must be connected exactly as shown.

AUT

O

OF

F

ON

Thermopile