ADLINK ASD25-SLC Series User Manual

Page 17

Advertising
background image

User's Manual

17

3.1.2.  Identify Device Data 

The following table details the sector data returned after issuing an IDENTIFY DEVICE command.  

Word 

F=Fixed 

V=Variable 

X=Both 

Default Value 

Description 

0 

F 

0040h 

General configuration bit‐significant 

information 

1 

X 

3FFFh 

Obsolete‐Number of logical cylinders (16,383) 

2 

V 

C837h 

Specific configuration 

3 

X 

0010h 

Obsolete‐Number of logical heads (16) 

4‐5 

X 

0h 

Retired 

6 

X 

003Fh 

Obsolete‐Number of logical sectors per logical 

track (63) 

7‐8 

V 

0h 

Reserved for assignment by the Compact Flash 

Association 

9 

X 

0h 

Retired 

10‐19 

F 

varies 

Serial number (20 ASCII characters) 

20‐21 

X 

0h 

Retired 

22 

X 

0h 

Obsolete 

23‐26 

F 

varies 

Firmware revision (8 ASCII characters) 

27‐46 

F 

varies 

Model number 

47 

F 

8010h 

7:0 – Maximum number of sectors transferred 

per interrupt on multiple commands 

48 

F 

0h 

Reserved 

49 

F 

2F00h 

Capabilities 

50 

F 

4000h 

Capabilities 

51‐52 

X 

0h 

Obsolete 

53 

F 

0007h 

Words 88 and 70:64 valid 

54 

X 

3FFFh 

Obsolete ‐ Number of logical cylinders (16,383)

55 

X 

0010h 

Obsolete ‐ Number of logical heads (16) 

56 

X 

003Fh 

Obsolete ‐ Number of logical sectors per logical 

track (63) 

57‐58 

X 

00FBFC10h 

Obsolete 

59 

F 

0101h 

Number of sectors transferred per interrupt on 

multiple commands 

60‐62 

125,045,424 

63 

F 

(64GB) 

Total number of user addressable sectors 

Advertising