AMT Datasouth M1 User Manual

Page 27

Advertising
background image

23


4.3.4 Set Media Black Mark Sensor and Calibrate

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns green/amber after 5 green blinks. (Any green/amber will
do during the 5 blinks).

The LED color will be changed in the following order:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green


4.3.5 Set Media Gap Sensor and Calibrate

Please follow the steps as below.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns red/amber after 5 green/amber blinks.

(Any red/amber

will do during the 5 blinks).

The LED color will be changed in the following order:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks)

solid green


4.3.6 Skip AUTO.BAS

PAL programming language allows user to download an auto execution file to flash memory. The
printer will run the AUTO.BAS program immediately when turning on printer power. The
AUTO.BAS program can be interrupted without running the program by the power-on utility.

Please follow the procedures below to skip an AUTO.BAS program.
1. Turn off printer power.

2. Press the FEED button and then turn on power.

3. Release the FEED button when LED becomes solid green.

The LED color will be changed in the following order:
Amber red (5 blinks) amber (5 blinks) green (5 blinks) green/amber (5 blinks)
red/amber (5 blinks) solid green

4. The printer will be interrupted to run the AUTO.BAS program.