The most important spares—overview, Heating in-between seasons, Chimney fire – Austroflamm Pallas User Manual

Page 8: Gaskets, Keramott, Other parts, Accessories, Important, Maintenance, Cleaning

Advertising
background image

Pallas

6 english

Heating in-between seasons

If you heat the stove in between seasons, when the
outside temperatures are higher, the flue gases may
not be able to escape completely and this may lead to
disturbances in the chimney draught, especially if the
temperatures are rising suddenly. The stove has to
be charged with less wood then and the primary air
has to be increased so that the wood can burn down
faster (with visible flames) and thus the chimney
draught can stabilize.

Chimney fire

A chimney fire may occur, due to sooting and
deposits in the chimney, if wrong or humid fuel is
used. In case of a chimney fire close all air inlets on
the fireplace/chimney immediately and call the fire
brigade. Please have an expert inspect your chimney
for cracks and air-tightness after the burning out of
the chimney.

4. THE MOST IMPORTANT SPARES—OVERVIEW

Gaskets

Description

Nr. drawing Part number

Flat gasket 8 x 2 mm

13

710096

Round gasket 6 mm (0,5 m)

14

710696

Round gasket 14 mm (2,1 m)

15

710338

Keramott

Description

Nr. drawing Part number

Bottom Keramott left

1

712766

Bottom Keramott right

2

712767

Bottom Keramott centre

3

712760

Rear, Keramott

4

712761

lateral Keramott right

6

712763

lateral Kermott left

5

712762

Keramoot baffle plate

7

712764

Keramott wood retainer

8

712765

Other parts

Description

Nr. drawing Part number

Pallas door glass

10

712759

Door Handle

11

712786

BA1 spring

12

715641

Stove lacquer

--

650002

Glass cleaner ½ litre

--

640070


Accessories

You can obtain floor plates of glass or steel, care products or the Heat Memory System for heat storage from
your certified dealer

.

IMPORTANT:

Have defective parts replaced by your certified dealer. This will guarantee that your stove

functions properly and safely.
The fireplae must not be amended

.

Maintenance

To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered surfaces are
to be cleaned only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel
surfaces

.

Cleaning

The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if
necessary more often, e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by
the chimneysweeper. Your chimneysweeper will inform you of the necessary inspection intervals. An expert
should inspect the stove annually.

order of Keramott installation acc. to numbering

3

4

7

8

1

2

5

6

Advertising