Troubleshooting – Desa GA3700 User Manual

Page 25

Advertising
background image

www.desatech.com

113109-01G

25

TROUbLEShOOTING

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

pOSSIBLE CAUSE

1. Ignitor electrode not con-

nected to ignitor cable

2. Ignitor cable pinched or

wet

3. Piezo ignitor nut is loose

4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode positioned

wrong

7. Ignitor electrode broken

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

REMEDY

1. Reconnect ignitor cable

2. Free ignitor cable if pinched

by any metal or tubing.
Keep ignitor cable dry

3. Tighten nut holding piezo

ignitor to base panel of log
set. Nut is located behind
base panel

4. Replace ignitor cable
5. Replace piezo ignitor
6. Replace pilot assembly

7. Replace pilot assembly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while

in PILOT position

4. Continue holding down

control knob. Repeat ignit-
ing operation until air is
removed

5. Contact local propane/LP

gas company

6. Clean ODS/pilot (see

Cleaning and Maintenance,
page 24) or replace ODS/
pilot assembly

7. Replace gas regulator

OBSERvED pROBLEM

When ignitor button is
pressed, there is no spark
at ODS/pilot

When ignitor button is
pressed, there is spark at
ODS/pilot but no ignition

Advertising