Installation, Air for combustion and ventilation – Desa GA3700 User Manual

Page 8

Advertising
background image

www.desatech.com

113109-01G

8

INSTALLATION

WARNING: Never install the

fireplace

• in a bedroom or bathroom

• in a recreational vehicle

• where curtains, furniture,

clothing or other flammable

objects are less than 36" from

the front and 42" from top of

fireplace; for side clearances

see Figure 8, page 10

• in high traffic areas

• in windy or drafty areas

CAUTION: This fireplace cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to fireplace. Installing

fireplace next to vinyl or cloth

wall coverings or operating

heater where impurities (such

as, but not limited, to tobacco

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps,

etc.) in the air exist, may discolor

walls or cause odors.

Figure 4 - Ventilation Air from Outdoors

Outlet

Air

Ventilated

Attic

Outlet

Air

Inlet

Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
and one within 12" of the floor. Connect these
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for
Combustion and Ventilation
for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.

AIR FOR COMbUSTION AND VENTILATION

Continued

NOTICE: This heater is intended

for use as supplemental heat.

Use this heater along with your

primary heating system. Do not

install this heater as your pri-

mary heat source. If you have a

central heating system, you may

run system’s circulating blower

while using heater. This will help

circulate the heat throughout the

house. In the event of a power

outage, you can use this heater

as your primary heat source.

WARNING: A qualified ser-

vice person must install fire-

place. Follow all local codes.

WARNING: Make sure the

selector switch is in the OFF po-

sition before installing heater

Advertising
This manual is related to the following products: