Using the setup modes, Product identification, Coding – Bonaire LV User Manual
Page 32: Auto-coding, Manual coding, Controls – installation / setup / commissioning

Multi-Appliance Manual Control
Controls – Installation / Setup / Commissioning
USING THE SETUP MODES
There are a series of available parameters that can assist the installer to set the unit up to
specification and tailor the control to meet the customer’s requirements. Carefully read these
instructions before entering the maintenance modes. These set up features cover Ducted
Evaporative Air Conditioning, Ducted Gas Central Heating and Add-on Refrigerated Air
Conditioning.
The Setup modes include:
Diagnostics
–
All products
Fan Speed Settings
–
All products
P
RODUCT
I
DENTIFICATION
The setup mode will cater for many options of heating / cooling unit configurations. As a result
there are a number of potential product classes that the manual control system will control. The
class is the first requirement for selection when coding or entering the setup mode.
Ducted Gas Heating Only
HEAT
Dual Cycle Refrigerated Air Conditioning
COOL
Ducted Evaporative Air Conditioning
COOL, FRESH AIR
Ducted Gas Heating and Evaporative Air Conditioning. HEAT, COOL FRESH AIR
CODING
A
UTO
-C
ODING
The manual control is only capable of controlling 1 product at a time. Options / combinations
available are:
To code the unit communications:
S
TEP 1
Ensure the control and communication cable(s) are connected.
S
TEP 2
The moment the power is applied to the control system, the control will scan for
all the new equipment that has been installed and powered on.
S
TEP 3
The powering up of a multiple configuration, a ducted central heater and a ducted
evaporative air conditioner, must happen within 10 seconds of each other for the
scan to find both units.
M
ANUAL
C
ODING
If the scan misses one of the units in a multiple configuration or you are adding a new product to
the configuration:
S
TEP 1
Turn the thermostat ON.
S
TEP 2
Press and hold the ON / OFF button for 3 seconds
to scan for the available products.
All the segments will be displayed during the
coding period.
Bonaire Control Systems