Setting up the control, Setting minimum fan speed, Setting maximum fan speed – Bonaire Deluxe Control (LV) - PNE User Manual

Page 10: Setting up the dump valve (where fitted), Etting, Ontrol

Advertising
background image

Manual Comfort Control

Control Installation & Setup

PNE2002 Series Control

Page 10

Setting Up The Control

The MANUAL control does not come with any maintenance functions to set the high or low fan speeds.

To set the high or low fan speeds an RF/LV digital control is required to set and save the settings in the

unit control.
Setting Minimum Fan Speed

1. Using the MANUAL/AUTO button set the unit to MANUAL

2. Using the HEAT/COOL/FRESH AIR button set the unit to

COOL FRESH AIR

3. Adjust the fan speed to the minimum fan speed level and

press ENTER.

4. Press the ENTER and ECONOMY/ BOOST buttons together

for approximately 10 seconds pressing the ENTER button
first.

5. The words FAN SPEED and a number under the room

temperature will flash.

6. Adjust minimum fan speed to a number suitable to the

system design. Ensure that the motor does not over-temp if
setting the fan speed lower.

7. Press ENTER to keep new fan speed.

Setting Maximum Fan Speed
Maximum fan speed can only be access after the minimum fan speed has been checked.

1. Using the MANUAL/AUTO button ensure MANUAL is still selected.

2. Using the ECONOMY/BOOST button set the unit to BOOST. Press ENTER.

3. Press the ENTER and ECONOMY/ BOOST buttons together for approximately 10 seconds pressing

the ENTER button first.

4. The words FAN SPEED and a number under the room temperature will flash.

5. Adjust maximum fan speed to 35 or a number to suit the system design.

6. Press ENTER to keep new fan speed.

Setting up the Dump Valve (Where Fitted)
A dump valve can be fitted to a unit using the MANUAL control. There are no timer control functions
available with this control. The dump valve solenoid is activated or deactivated when the pump

operation is used.