GLOW UP

1

2

8

MANUAL ZOOM - AERIAL

Aerial

NOTES: To achieve

best wireless perfor-

mance, it is recom-

mended to position

GlowUp with the aerial

side facing the tran-

smitter, when possible.

Manual zoom - Fig. 8

The GlowUP has a manual zoom located on the back of the projector head.

RDM CONTROLS IMPLEMENTED FOR GLOWUP SERIES

Control

PID

GET

SET

Description controller side

DEVICE_INFO

0x0060

X

IDENTIFY_DEVICE

0x1000

X

DMX_START_ADDRESS

0x00F0

X

X

SOFTWARE_VERSION_LABEL

0x00C0

X

SUPPORTED_PARAMETERS

0x0050

X

PARAMETER_DESCRIPTION

0x0051

X

DMX_PERSONALITY

0x00E0

X

X

DMX_PERSONALITY_DESCRIPTION

0x00E1

X

MANUFACTURER_LABEL

0x0081

X

DEVICE_LABEL

0x0082

X

X

SENSOR_DEFINITION

0x0200

X

SENSOR_VALUE

0x0201

X

RECORD_SENSORS

0x0202

X

DEVICE_MODEL_DESCRIPTION

0x0080

X

Gathers information from the device
Makes the red leds on the addressed device pulse
Reads or sets the DMX address
Reads the firmware version
Gathers the PIDS on the non-basic controls
Gathers information on the controls related to the manufacturer
Reads or sets the channel mode
Reads the description of the channel mode
Reads the manufacturer name
Reads or writes a label on the device
Reads the description of the sensors present
Reads the level of the led temperature sensor
Saves the current temperature level
Reads the text description of the model