118

Figure 7-41

Please refer to the following sheet for detailed information.

Parameter Function

Event
Type

There are three types: Motion detection/video loss/Camera Masking.

Channel

Select channel name from the dropdown list.

Enable

You need to draw a circle to enable motion detection function.

Sensitivity There are six levels. The sixth level has the highest sensitivity.

Region

z

There are six levels. The sixth level has the highest sensitivity.

z

Region: If you select motion detection type, you can click this button
to set motion detection zone. The interface is shown as in

X469H469H469H421H

Figure

7-41

X

. There are PAL 22X18/NTSC 22X15 zones. Right click mouse

you can go to full-screen display mode. Do remember clicking OK
button to save your motion detection zone setup.

Period

z

Motion detection function becomes activated in the specified
periods.

z

There are six periods in one day. Please draw a circle to enable
corresponding period.

z

Select date. If you do not select, current setup applies to today only.
You can select all week column to apply to the whole week.

z

Click OK button, system goes back to motion detection interface;
please click save button to exit.

Anti-dither System only memorizes one event during the anti-dither period. The

value ranges from 0s to 15s.

Normal
out

z

There is 2-channel alarm output.

z

Corresponding to motion detection alarm output port(multiple
choices)

z

Enable alarm activation function. You need to select alarm output
port so that system can activate corresponding alarm device when
alarm occurs.

Alarm
latch

System can delay the alarm output for specified time after alarm end
The value ranges from 10s to 300s.

Alarm
upload

System can upload the alarm signal to the centre (Including alarm
centre.

Record
channel

System auto activates motion detection channel (multiple choices) to
record once alarm occurs (working with motion detection function).
Please note you need to go to Chapter 4.4 Schedule to set motion
detection record period and go to chapter 4.2 Manual Record to set
current period as auto record.

Record
latch

System can delay the record for specified time after alarm ended. The
value ranges from 10s to 300s.

Email

If you enabled this function, System can send out email to alert you
when alarm occurs and ends.

Tour

z

Display the selected video in local monitor window.

z

Tour interval and tour mode are set in DVR local menu (chapter
5.3.9 Display )