Da-Lite Large Cosmopolitan Electrol User Manual

Page 9

Advertising
background image

9

Screen Adjustment For 240V Screens With A Built-In Low Voltage Control

1. Remove the cover plate from the 3-button wall switch and

remove the switch from the junction box.

2. Locate small 3-position switch on back of wall switch. See

wiring diagram.

3. To adjust the down limit switch, slide the 3-position switch to

the down position. Press and hold the down button to run the
screen down to the desired stop position. Release the button
to stop the screen. DO NOT PUSH THE STOP BUTTON.

4. When the screen is in the desired down position, slide the

3-position switch to the off (center) position. The down limit
switch is now set.

5. To adjust the up limit switch, slide the 3-position switch to the

up position. Press and hold the up button to run the screen
up to the desired stop position. Release the button to stop
the screen. DO NOT PUSH THE STOP BUTTON.

6. When the screen is in the desired up position, slide the

3-position switch to the off (center) position. The up limit
switch is now set.

7. To test limit switch setting, make sure the 3-position switch

is in the off (center) position. Press and release the up or
down button on the wall switch to operate the screen.

8. Replace switch and cover plate on the wall.

NOTE: If stop button is pressed, the wall switch will reverse
direction. To correct this, press the stop button again. This
will reset the switch. You will have to re-set both the up
and the down settings.

IMPORTANT NOTE: The wall switch is REQUIRED to make
any limit switch adjustments, EVEN if a third party control
system is used. Therefore, it is advised to wire the switch or
provide a 4-conductor connection that is accessible.

Advertising