Da-Lite Large Dual Masking Electrol User Manual

Page 5

Advertising
background image

5

Screen Adjustment For 220V/240V Screens

Large Dual Masking Electrol® Instructions

CAUTION! The mask should not be field adjusted for more or less drop.

ATTENTION! Le masque ne doit pas être ajusté sur place pour régler la chute.

Surface travel is stopped automatically in the fully opened and closed positions by limit switches that are properly adjusted at Da-Lite.
Should it be necessary to adjust for more or less drop of picture, proceed in the following manner:

NOTE: Use a screw driver or allen wrench to make adjustments.

More screen drop

1. Remove access panel (Fig. 1).

2. Place operating switch in

“down” position.

3. When the screen stops, turn the

“down” limit knob (Fig. 2)

one-quarter turn counterclockwise. Test by raising picture
surface approximately two feet, then lower again. Repeat until
desired picture surface position is attained.

NOTE:

Must leave 1-1/2 wraps of fabric on roller!

4. Replace access panel.

Less screen drop

1. Remove access panel. (Fig. 1).

2. Raise picture surface approximately two feet

above desired level.

3. Place operating switch in

“off” position.

4. Turn the

“down” limit knob (Fig. 2) one-quarter turn

clockwise. Test by raising picture surface approximately
two feet, then lower again. Repeat until desired picture
surface position is attained.

5. Replace access panel.

Mask

Screen

Mask Motor

4 – Wire

Mask Motor

4 – Wire
Screen Motor

Screen Motor

220 V. AC 50 Hz
Input

Brown

Black

Blue

Green/Yellow

Up

Off

Down

Up

Off

Down

240V Wiring Diagram

Brown (Hot)
Blue (Common)
Ground Wire

Brown
Black
Blue
Green/Yellow

Up

Down

Common

Ground

Up
Down
Common
Ground

Double Gang J-Box

Provided By Da-Lite

Protective Earthing
Stud Inside Junction Box

IMPORTANT NOTE:
Switch junction box must be connected to
ground using the procective earthing screw.

Junction Box
Located in
Screen Housing

Junction Box
Located in
Screen Housing

Advertising