Da-Lite Tensioned Cosmopolitan Electrol User Manual

Page 5

Advertising
background image

5

CAUTION: The projector must be turned off before
connecting the trigger wires to the projector. Failure to do
so may damage the controller.

ATTENTION: Le projecteur doit être éteint avant de brancher
les fils de déclenchement à celui-ci. Tout manquement à
cette instruction pourrait endommager le contrôleur.

Use 2-conductor 20-24 gauge wire to extend the low voltage
connection from the projector’s 5 or 12-volt screen trigger output
to the length required to reach the VPI. When extending the low
voltage connection from the projector’s screen trigger output
polarity does not matter. The red and black wires from the VPI
are interchangeable.

120V Wiring Diagram with Optional Built-In Video Projector Interface

5/12 Volt Screen
Trigger On Projector

Ground–Must Be Connected
To Building Ground

UP

STO

P

DOWN

Power Input 120VAC / 60Hz

Green (Ground)

Black (Hot)

White (Common)

Power

Wire

Data Cable

RJ-45 Jack

RJ-45 Receptacle

RJ-22 Output

RJ-22 Jack

RJ-22

Inputs

RJ-22

Jack

LED

Up

Limit

Tactile

Button

Down

Limit

Tactile

Button

Front Of

Wall Switch

Back Of

Wall Switch

Black

Red

VPI Trigger Module

Dry Contacts

Up

Down

Common

Bus

5V

BUS

BUS

COM

5V

BUS

IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
3-conductor connection that is accessible.

3-conductor 20-24 gauge wire can be used in place of the
supplied RJ-14 cable to connect the wall switch. Connect the
BUS terminals on the wall switch to the corresponding BUS
terminals on the splitter board.

Advertising