Da-Lite Curved Multi Format Imager User Manual

Page 11

Advertising
background image

11

Multi Format Imager Intermediate Stop Adjustment

Multi Format Imager Limit Travel Adjustment

1. To adjust intermediate stopping positions make sure both

masks are completely retracted into the frame. Press the left
mask ">" button. The mask will start to move outward. Press
the stop button at the position you want it set to. If you go
too far outward press the left mask "<" button and the mask

will retract back into the case.

2. Press the right mask"<" button. The mask will start to move

outward. Press the stop button at the position you want it set
to. If you go too far outward press the right mask ">" button
and the mask will retract back into the case.

3. Once both masks are at the desired stopping position. Press

and hold Preset 1, Preset 2, Preset 3 or Preset 4 button on
remote for 10 seconds.

4. Repeat steps 1 thru 3 for other Preset locations.

1. To make limit travel adjustments you will need the 3-button

low voltage wall switch that was shipped with your masking
screen.

2. Locate the junction box cover on bottom frame assembly.

Remove two screws holding junction box cover on the
bottom of frame.

3. Unplug the 6P6C cable that goes from QEYE of primary

splitter to QAUX of secondary splitter as shown in Figure 17.

4. Unplug the IR eye end of the 6P4C cable that goes from the

QEYE of primary splitter to the IR eye.

5. To adjust travel of left mask. Plug the 6P4C cable into the

back of wall switch as shown in Figure 18. The wall switch LED

will blink green twice when the 6P4C cable is plugged in.

Primary Splitter

Switch

LED

"Up" Limit

Button

"Down" Limit

Button

RJ–22

Jack

Secondary Splitter

T6 From

Quax To Qeye

Figure 17

Figure 18

Advertising