6

1

2

3

4

5

6

Modifying the Extension of the Mask

1. You can increase the extension of a mask up to 3" past the

factory preset stop, or you can decrease the extension by
approximately 4-6" from the factory preset stop. Do not
attempt to modify a mask extension beyond these
recommended amounts.

2. The limit switches are accessed through openings located on

the left side of the frame as shown in Figure 8.

3. Horizontal mask units have limit switches at the top and

bottom of the screens, a set for each roller tube.

WARNING! The up limit switch(es) retract the batten

further into the unit. Adjusting it is not advised. Refer to 1,
3 or 5 as appropriated in Figure 8.

AVERTISSEMENT! Le(s) interrupteur(s) de fin de course
supérieur(s) rétracte(nt) la latte à l'intérieur de l'unité. Le
réglage n'est pas recommandé. Référez-vous au points 1,
3 ou 5 tel qu'indiqué dans la figure 8.

To Increase a Mask's Fully Extended (Mask Down)
Stop Position:

1. Lower the mask to its current stop position.

2. Locate the down limit switch(es) located on the left side of

the frame. Refer to 2, 4 or 6 as appropriate in Figure 8. Use an
Allen wrench to turn the switch in a counterclockwise
direction. If the power is on, the mask will drop incrementally
as the switch is turned.

NOTE: One complete turn of the

switch will make approximately a 1/2" change in the mask's
stop position.

To Decrease the Screen Extension:

1. Lower the mask until it is extended about halfway down.

2. Locate the down limit switch(es) located on the left side of

the frame. Refer to 2, 4 or 6 as appropriate in Figure 8. Use
an Allen wrench to turn the switch in a clockwise direction.
NOTE: One complete turn of the switch will make
approximately a 1/2" change in the mask's stop position.

3. Activate the mask in the down direction until it reaches

the newly reduced stop position. Repeat this procedure
until the desired stop position is reached.

Once you have made the adjustment, whenever you lower
the mask, it will automatically stop at the new position.

Adjusting The Mask Extension (Continued)

Figure 8

Screen

Horizontal Mask

Horizontal Mask

Vertical Mask

Screen Care And Cleaning

With reasonable care, you expect many years of trouble-free use

of your Da-Lite projection screen.

We encourage you to keep your screen clean. Avoid getting any
foreign material on the screen. It may not be possible to remove
scratches, paint, ink, etc.

General Maintenance

The screen surface on your Multi-Mask Imager is delicate.
Special attention to these instructions should be followed
when cleaning.

• A draftsman-style brush may be used to lightly whisk away

any loose dirt or dust particles. (This type of brush is usually
available at office supply stores.)

• For tougher spots, use a mild solution detergent, water and a

soft cloth. Rub lightly. Blot with a damp sponge to absorb
excess water.

Do not use any other cleaning materials on the screen.

Replacement Parts and Service

No user-serviceable parts are contained within the unit.
Contact your dealer or the factory if you require part
replacement or service.