Pro imager installation – Da-Lite Pro Imager Horizontal Masking System User Manual

Page 5

Advertising
background image

5

Pro Imager Installation

Do

wn R

ed

Up Black

Common

Whit

e

Black With
Yellow

Black

White

Red

Up

Down

Rocker

Switch

AC Common
AC Hot

Operating Switch,
Switch Box, And
Plate Furnished
With Screen
(SPDT With
Center Off)

120V. 60-Hz 2.5 Max. Amp

To Motor

In Multiple Control
Installations This Switch
Is Replaced By The Low
Voltage Control,
Operated From Push
Button Stations.

This Switch Cannot Be Used With LVC.

NOTE: A single switch cannot be used to operate more than

one screen. Contact the factory for further information.

Side View

Of Switch

And Box

120V Wiring Diagram

220 / 240V

Wiring Diagram

Br

o

wn (Up)

Black (Do

wn)

Blue (Common)

Brown/Yellow

Up

Off

Down

Rocker

Switch

Blue AC Common

Brown AC Hot

Operating Switch,
Switch Box, And
Plate Furnished
With Screen.

Blue Jumper Wire

To Motor

NOTE:

Must Be Wired To Conform To
Local Wiring Code. This Switch
Cannot Be Used With L.V.C.

220/240V. AC 50Hz.
2 Amp. Max

Junction

Box

In Multiple Control
Installations This Switch Is
Replaced By The Low
Voltage Control, Operated
From Push Button Stations.

NOTE: A single switch cannot be used to operate more than

one screen. Contact the factory for further information.

Rear View Of DPDT,
With Center Off

Off