straddling the two pins labeled “NORMAL” which are nearest the front of the iScan board.
21) Remove this jumper from its current position by grabbing the top of the jumper and pulling
directly away from the PC board.
22) Push the jumper onto the two pins closest to the rear of the iScan board, labeled “C-SYNC.”
Modifying Sync-on-Green Jumper 
Setting 
23) To configure the unit to merge sync with Green,
you should work with the jumper labeled 
“SYNC-ON-G.” There should already be a 
jumper on two of the pins, labeled “NORMAL.” 
24) Remove this jumper and push onto the two pins
closest to the rear of the iScan board, labeled 
“SYNC-ON-G.” 
Modifying VCR Mode Jumper 
Setting 
25) To enable the iScan Plus v2’s time base corrector, you will need to modify the setting of a
jumper which is not labeled. See the diagram above for the location. A plastic jumper should 
already be straddling the two pins that are closest to the rear of the board. 
26) Remove this jumper from its current position by grabbing the top of the jumper and pulling
directly away from the PC board.
27) Push the jumper onto the two pins closest to the front of the board. Note that this is the
opposite convention from the other two jumpers which are in NORMAL mode when on the 
two rear-most pins. 
Reassembling the iScan Plus v2
28) Push the PC board back into the
unit slowly, being careful that the 
bottom slots in the housing are 
used to guide the board and that 
the front LEDs appear through 
the front panel. Verify that the 
front panel switches protrude 
fully through the panel. 
29) Replace the copper grounding
clip so that it tucks between the 
power connector and the PC 
board and so that it makes contact 
with the metal enclosure. (See below).
 
 
30) Place the EMI gasket and the back panel over the 
connectors and make sure that it is flush with the 
sides of the housing. 
31) Screw the two screws into the rear panel of the
unit.
 
You may want to attach a note to the iScan Plus v2 
specifying which internal setting you have changed. 
The iScan board sits in the bottom slot
Jumper is on NORMAL pins