background image

Carpenters

Square

Measuring

Tape

Level

Drill & Hole Saw set

Gloves

Safety Glasses

Flashlight

Electrical Access

Cabinets

Square

and

Plumb

34 3/4”

From

Underside

of

Countertop

to Floor

24”

6”

24”

Min.

1-

1

/2” dia. hole

*if electical

outlet is in

adjacent

cabinetry

2”

TOOLS YOU

WILL NEED

FOR YOUR SAFETY:

While performing installations described in
this section, gloves, safety glasses, or goggles
should be worn.

PREPARING THE

ENCLOSURE

ELECTRICAL REQUIREMENTS: The appliance must be connected to an
individual, properly grounded electrical outlet, protected by a 15 or 20 ampere circuit
breaker or time delay fuse.

• It is recommended that you do not install the wine cooler into a corner (i.e. directly beside a wall). This is to
allow the door to have a greater then 90° opening swing. A limited door swing may lead to damaging the
door gasket.

• The rough cabinet opening must be on a level floor area and at least 24” deep by 24” wide. The opening
should also have a height of at least 34 3/4”.

• The electrical oulet may be positioned from within either side of the adjacent cabinetry, or the rear of the
shaded area (as shown in Fig E).

• If the electrical outlet is located inside the adjacent cabinetry, cut a 1-1/2” diameter hole to admit the power
cord. If the cabinet wall is metal, the hole edge must be covered with a bushing or grommet.