Debris tank, Fx20 operator’s manual – Ditch Witch FX20 User Manual
Page 81
Advertising

Service - 80
FX20 Operator’s Manual
As Needed
CMW
Debris Tank
Clean Primary Shutoff Valve
Clean primary shutoff valve as needed. Replace primary shutoff valve as needed.
To clean:
1.
Open tank door. See “Drain Tank” on page 48.
2.
Spray valve housing inside vacuum tank with high-pressure water.
3.
Store water pressure hose.
4.
Close tank door. See “Drain Tank” on page 48.
To remove:
1.
Disconnect hose from elbow.
2.
Remove bolts (1) and pull out valve housing
(2).
3.
Remove ball (3).
4.
Clean ball and housing with high-pressure
water.
5.
Replace ball and housing.
6.
Tighten nuts.
Advertising