Locate - 38
UtiliGuard™ Series Operator’s Manual
Locate Active Signals
CMW
®
Signal is transferring to other cables.
•
Lower the frequency.
•
Lower the power level.
•
Use direct connection, if possible, or use induction
clamp.
•
Move the ground stake away from the target cable and
away from other buried cables.
•
Apply signal at the point where the target cable is
farthest from the other cables.