Pyramid style shroud, 7pyramid style shroud minimum dimensions – DuraVent DuraTech Shroud User Manual

Page 7

Advertising
background image

7

Pyramid Style Shroud

Minimum Dimensions

Chimney

Diameter

(inches)

Min

Height

H 1 (inches)

Min

Length

L (inches)

Min

Width

W (inches)

Min

Base

B (inches)

Min

Height

H 2 (inches)

5

17

13

13

7

1.0

6

17

13

13

7

1.0

7

17

17

17

11

1.0

8

17

17

17

11

1.0

10

22

24

24

18

1.5

12

23

24

24

18

2.0

14

24.5

28

28

22

2.0

16

25

28

28

22

2.5

18

30

35

35

24

3.0

20

30

35

35

24

3.0

22

30

39

39

24

4.0

24

30

39

39

24

4.0

Figure 4

Table 3: Pyramid Style Shroud Minimum Dimensions

Shaded area represents screened Open Area. Actual shape

of Shroud may vary as long as minimum dimensions and

minimum Open Area requirements are met.

L: Minimum length of Shroud top opening

W: Minimum width of Shroud top opening

H1: Minimum total height of Shroud

B: Minimum length of opening along base

H2: Minimum height of opening along base

H2

W

B

H1

L

PYRAMID STYLE SHROUD

The Pyramid style shroud is roughly square

or rectangular with an open top for exhaust as

well as openings along the base of the four

(4) sides. (Figure 4) Table 3 lists the minimum

Shroud dimensions, including the minimum

height and length of the base openings on the

sides, depending on the diameter of DuraTech

chimney.