Venting installation instructions, Continued – Desa VC42P SERIES User Manual

Page 10

Advertising
background image

www.desatech.com

116236-01A

10

Horizontal High

Wind Square

Termination

Wall Firestop

45° Elbow

Figure 14 - Horizontal Termination Configuration for Square or

Round Terminations

45° Elbow

Wall

Firestop

Horizontal

Round

Termination

Exterior Portion of

Wall Firestop (Round

Termination Only)

GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square termination
(up to 12" horizontal pipe)
• NOT FOR CORNER INSTALLATION

VENTING INSTALLATION

INSTRUCTIONS

Continued

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

Adjustable

Pipe 12" Max.

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives

for venting with horizontal termination. Each figure includes a chart

with critical minimum and maximum dimensions which MUST be

met. IMPORTANT: Remember that a horizontal run of venting must

have a 1/4" rise for every 12" of run toward the termination.

NOTICE: Do not seal termination cap to vent pipe.

Cap must be removable for vent inspection and

maintenance.

Figure 13 - Typical Horizontal Termination Cap Mounting with

Additional Siding Standoff Installed

Siding Standoff

Screws

High Wind

Termination

Apply Mastic to

Outside Edge of

Standoff

Exterior Wall

with Vinyl Siding

10

3

/

4

" x 10

3

/

4

" Framed

Opening

Maintain 1"

Minimum Air

Space Around

Outer Pipe When

Penetrating a Wall

Minimum Pipe

Overlap 1

1

/

4

"

Wall

Firestop

Direct Vent

Pipe

WARNING: Never run vent downward as this may

cause excessive temperatures which could cause a

fire. Operation of improperly installed and maintained

venting system could result in serious injury, property

damage or loss of life.

9.

Combustible Exterior Wall Only:

Slide wall firestop against

interior wall surface and attach with screws provided. See

Figure 13 for horizontal termination details.

10. Place fireplace into position and shim with noncombustible ma-

terial if needed. Nail or screw side flanges to framing to secure

unit in place. IMPORTANT: Make sure fireplace is level before

securing. If fireplace is not level it will not work properly.

Round Termination

Square Termination

Vertical (V)

Horizontal (H)

32

3

/

4

" min.

17" max.