Chapter 3 - Input/Output Interfaces

82

FT 3120 / FT 3150 Smart Transceiver Data Book

to drive an audio transducer, or to drive a frequency to voltage converter to generate an analog output. See
Figure 3.45.

Frequency Resolution and
Maximum Range at 10MHz

Figure 3.45 Frequency Output Latency Values

A new frequency output value will not take effect until the end of the current cycle. There are two exceptions to this
rule. If the output is disabled, the new (non-zero) output will start immediately after

t

fout

. Also, for a new output value

of zero, the output is disabled immediately and not at the end of the current cycle.

A disabled output is a logic zero by default unless the invert keyword is used in the I/O object declaration. The
resolution and range for this object scale with FT Smart Transceiver input clock rate, for example: resolution
from 0.1 to 12.8 µs and range from 6.55 to 839 ms at 40MHz.

Symbol

Description

Typ @ 10MHz

t

fout

Function call to output update

96 µs

t

ret

Return from function

13 µs

System Clock

Divide Chain

Timer/Counter 1

Timer/Counter 2

IO10

IO9

IO8

IO0
IO1
IO2
IO3
IO4
IO5
IO6
IO7

High Current Sink Drivers

END

OF io_out()

t

ret

NEW OUTPUT

APPEARS ON PIN

HARDWARE

UPDATED

INTERNALLY

t

fout

START

OF io_out()

TIME

FREQUENCY

OUTPUT

ONE CYCLE

CLK

Resolution

Range

Unit

0

0.4

26.21

µs

1

0.8

52.42

µs

2

1.6

104.86

µs

3

3.2

209.71

µs

4

6.4

419.42

µs

5

12.8

838.85

µs

6

25.6

1677

µs

7

51.2

3355

µs