Trouble- shooting, Warning – Desa GVC35NA User Manual

Page 27

Advertising
background image

27

100749

TROUBLE-

SHOOTING

Continued

WARNING

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call

the fire department.

POSSIBLE
CAUSE

1. Metal expanding while

heating or contracting
while cooling.

1. Heater burning vapors

from paint, hair spray,
glues, etc.

2. Gas leak.

See Warn-

ing statement at
top of page.

1. Heater not venting

correctly. Vent safety
switch shuts off
heater.

2. Low line pressure.

3. Pilot partially clogged.

1. Gas leak.

See Warn-

ing statement at
top of page.

2. Control valve dam-

aged.

1. Foreign matter between

control valve and burner.

2. Gas leak.

See Warn-

ing statement at
top of page.

3. Foreign fumes in area

of heater being drawn
through burner com-
bustion.

OBSERVED
PROBLEM

Heater produces a
clicking/ticking noise
just after burner is lit
or shut off.

Heater produces
unwanted odors.

Heater shuts off in
use.

Gas odor even when
control knob is in
OFF position.

Gas odor during
combustion.

REMEDY

1. This is common with

most heaters. If noise is
excessive, contact quali-
fied service person.

1. Ventilate room. Stop us-

ing odor causing products
while heater is running.

2. Find and correct all leaks

(see Checking Gas
Connections
, page 13).

1. Check venting system.

If damaged or blocked,
repair. If venting
system is OK, have
qualified service person
replace vent safety
switch, wire harness, or
thermocouple inter-
rupter.

2. Contact local natural

gas company.

3. Clean pilot (see Clean-

ing and Maintenance,
page 23).

1. Find and correct all leaks

(see Checking Gas
Connections
, page 13).

2. Replace control valve.

1. Take apart gas tubing and

remove foreign matter.

2. Find and correct all

leaks (see Checking Gas
Connections
, page 13).

3. Ventilate area around

heater to remove any
foreign fumes.

Advertising