Testing the fg-500 function generator, Final assembly (continued) – Elenco 100kHz Function Generator in Kit Form User Manual
Page 10

-9-
r Remove the backing from each rubber foot and
place them in the locations shown in Figure M.
r Assemble the top and bottom case sections and
fasten with four 2.8 x 8mm self-tapping screws as
shown in Figure M. Make sure the slots on the
side line up with one another.
r Turn the shafts on the two potentiometers and
rotary switch fully counter-clockwise. Push the
three knobs onto the shafts so that the line on the
knobs are on the points shown in Figure N.
TESTING THE FG-500 FUNCTION GENERATOR
The unit may be tested by following the 4 steps listed below. Should any of these tests fail, refer to the
Troubleshooting Guide.
1) SET THE SWITCHES AND POTS AS FOLLOWS:
On/Off
On
Range
10
Frequency
Maximum (clockwise)
Amplitude
Maximum (clockwise)
Sine/Triangle
Set Sine/Triangle switch to Sine position
Figure M
2.8 x 8mm Screws
2.8 x 8mm
Screws
Rubber feet
Rubber
feet
Slot
Figure N
FINAL ASSEMBLY (continued)