Measurement

Figure 8 shows a simplified diagram of the h

FE

measuring circuit for PNP transistor. Here the range switch is in

the X10 ohms position and the transistor circuit takes the place of the external resistor in the ohms measurement.

The higher the h

FE

of the transistor, the more current flows in the external circuit and the lower the effective

resistance. The meter reads this resistance and the h

FE

of the transistor may be read on the h

FE

scale.

Figure 8

-17-

Battery Test

Figure 9 shows a simplified diagram of the battery measuring circuit. The battery voltage is measured under a
0.25A load.

DC NULL Test

Figure 11 shows a simplified diagram of the DCV (NULL) circuit. The meter is set to 0 on the DCV (NULL) scale.
Positive or negative voltage applied to the terminals causes the meter to swing in either direction.

Buzzer Test

Figure 10 shows a simplified diagram of the audio continuity circuit. When a 20

Ω load or less is place across

the terminals, transistor Q3 conducts and allows Q3 to oscillate.