Specifications, F - 104, F (0 – Elenco 050VDC @ 3A LCD Display User Manual

Page 6: F - +40

Advertising
background image

-5-

• Never move or pull the power supply using the power cord

or output lead.

• The unit is designed for INDOOR USE ONLY.

SPECIFICATIONS

Input Voltage

104 – 127VAC (60Hz)
207 – 253VAC (50Hz)

Protection

Current limit and
short circuit protection

Voltage Display Accuracy

LCD +1% +2 digits,
Analog +2.5% FSR

Current Display Accuracy

LCD +2% +2 digits,
Analog +2.5% FSR

Environment:

32

O

F - 104

O

F (0

O

F - +40

O

C),

relative humidity <90%

Dimensions (H x W x L)

6¼” x 5¼” x 11½”
(15.9 cm x 13.3 cm x 29.2 cm)

Weight

10.1 lbs. / 4.58 kg. (XP-605)
9.85 lbs. / 4.47kg. (XP-752A)

Model

Output

Current

Line Regulation

Load Regulation

Ripple & Noise

CV

CC

CV

CC

CV

CC

XP-752A

0-50V

3A

< 0.01% +1mV < 0.2% +1mA < 0.01% +3mV < 0.2% +3mA

< 0.5mV rms

< 3mA rms

XP-605

0-30V

5A

< 0.01% +1mV < 0.2% +1mA < 0.01% +3mV

< 3A

< 0.01% +5mV

> 3A

< 0.2% +3mA

< 3A

< 0.2% +5mA

> 3A

< 0.5mV rms

< 3A

< 1.0mV rms

> 3A

< 3mA rms

< 3A

< 6mA rms

> 3A

Advertising