0 technical data – ENMET SMARTLOGGER User Manual

Page 17

Advertising
background image

SMART LOGGER

ENMET Corporation

11

6.0 Technical Data

6.0 Technical Data

Manufacturer:

OLDHAM FRANCE S.A.

Function:

Single oxygen or toxic gas detector with interchangeable SMART BLOCK

Type:

SMART LOGGER

Case:

ABS, shock proof

Configuration:

Oxygen or one toxic gas, interchangeable sensors

Detectable gases:

Refer to table, Section I

Auto zero:

If requested at turn on, and when the charger is connected.

Measurement:

Continuous

Sensor:

Interchangeable SMART BLOCK

Display:

LCD (with backlight when initiated)

Sensor fault:

Continuous alarm

Battery fault:

Displayed, audible and visual alarm

Alarms:

Oxygen: 2 instantaneous thresholds
Toxic: 1 instantaneous threshold
1 TWA threshold
1 STEL threshold
Audible and visual alarm, concentration displayed on screen

Output:

(option) - On serial printer for events Speed: 9600 Bauds, 8 bits, parity pair, 1 stop bit, protocol
XON/XOFF
- On PC: maintenance and supervision software SMARTCOM, data bases, LOTUS, EXCEL

Earphone:

(option) Characteristics defined in the certification
Inductance < 1.5 µH
Capacitance < 0.8 µF

Power supply:

9V DC primary cell or rechargable battery

Mounting:

In the pocket or on the belt with clip

Autonomy:

100 h with primary cell, 24 h with rechargeable battery

Weight:

210 g. Dimensions : 130 x 61 x 43 mm

Warranty:

12 months

Certification:

CENELEC Ex EEx ia IIC T4

Specification subject to change without notice.