2 interference gases – ENMET SPECTRUM-RAL-DC User Manual
Page 11
Advertising

8
2.2 Interference Gases
Some gases other than CO cause a sensor response, and thus are termed "interference gases". Known
interference gases are as follows:
Gas
Concentration
Reading
in ppm
in ppm
Hydrogen
1,000
100+
Nitric oxide
100
25
The following levels of gases are known to cause no sensor response:
Gas
Concentration
Ammonia
100 ppm
Carbon dioxide
5,000 ppm
Chlorine
5 ppm
Ethylene
*
2 %
Gasoline vapor
*
saturated
Hydrogen cyanide
10 ppm
Hydrogen sulfide
*
10 ppm
Isopropanol
*
1,025 ppm
Methane
10,000 ppm
Nitrogen dioxide
*
10 ppm
Sulfur dioxide
*
10 ppm
*For indicated gases or vapors, prolonged exposure may reduce the efficiency of the sensor filter.