Sensor, Span, Calibration point – ENMET EX-5155 User Manual
Page 12
 
EX-5155-MOS
ENMET Corporation
10
 
 
Table 3: Examples of Standard and Non-Standard Calibration Gas
Gas
Range
Alarm 1* Alarm 2* Alarm 3*
Sensor
Part Number
Span
Calibration Gas
Calibration
Point
Gas Type/ Standard
Methyl Chloride
0 – 400 
PPM 
100 PPM
200 PPM
300 PPM
03015-000
100 PPM 
Methyl Chloride 
100 PPM 
Methyl Chloride 
Carbon Monoxide
0 – 400 
PPM 
35 PPM
50 PPM
100 PPM
03011-000
100 PPM 
Carbon Monoxide 
100 PPM 
Carbon Monoxide 
Hydrogen Sulfide
0 – 100 
PPM 
10 PPM
20 PPM
50 PPM
03015-000
100 PPM 
Carbon Monoxide 
20 PPM 
Hydrogen Sulfide 
Hydrogen
0 – 1000 
PPM 
200 PPM
500 PPM
800 PPM
03016-000
800 PPM Hydrogen
800 PPM Hydrogen
Gas Type/ Non – Standard
Considered Special Calibrations, use for examples only. Consult
ENMET
for specifications and availability.
Ammonia
0 – 300 
PPM 
150 PPM
300 PPM
300 PPM
03019-000
300 PPM Ammonia
See Addendum 
Ammonia Calibration 
Freon 134A
0 – 2000 
PPM 
500 PPM
1000 PPM
1500 PPM
03032-000
2% LEL Methane
1200 PPM Freon 134
Freon 12
0 – 2000 
PPM 
500 PPM
1000 PPM
1500 PPM
03032-000
300 PPM 
Carbon Monoxide 
1200 PPM Freon 12
Freon 22
0 – 2000 
PPM 
500 PPM
1000 PPM
1500 PPM
03032-000
2% LEL Methane
730 PPM Freon 22
Acetone
0 – 2000 
PPM 
500 PPM
750 PPM
1000 PPM
03016-000
500 PPM Hydrogen
1150 PPM Acetone
Methylene Chloride
0 – 200 
PPM 
25 PPM
50 PPM
100 PPM
03015-000
100 PPM 
Methyl Chloride 
140 PPM Methylene 
Chloride 
*
N
OTE
:
These internal sensor/transmitter alarms are independent of the 4-20mA Controller alarm point settings.