Creating and Generating Reports
OTDR
183
Generating a Report
Test and Cable Setup for main and reference traces:
file name, OTDR model, software version, wavelength,
distance, IOR, RBS, acquisition time, pulse width, file
type, serial number, splice loss detection, reflectance
detection, end-of-fiber detection, and helix factor.
In Template mode, only the information of the current
trace will be displayed.
By default, this item is selected.
X
X
X
Comments
By default, this item is selected.
X
X
X
Link measurement: Span loss, Span length, Average
loss, Average splice loss, and Span ORL.
By default, this item is selected.
X
X
X
Markers: marker information: a, A, b, B, and A to B
distances, as well as A to B attenuation, loss, and ORL.
By default, this item is selected.
X
X
Event table: If you selected the Mark faults in event
table feature from the OTDR setup, the failed results
will appear in red and bold on a white background.
Otherwise, they will not be “highlighted”.
By default, this item is selected.
X
X
X
Item appearing on the report
Auto
mode
Advanced
mode
Template