10 replacement of parts – Glow-worm BBU 45/4 User Manual

Page 30

Advertising
background image

30

2000225023C

10 Replacement of Parts

6188

Diagram 10.6

SECURING
SCREW (4)

COMBUSTION
CHAMBER
FRONT COVER

SIDE
INSULATION
PIECE

REAR INSULATION
PIECE

SIDE INSULATION
PIECE

FRONT
INSULATION PIECE

10.10 Overheat Cut-off Safety Device (Sealed
systems only)

Unclip the overheat cut-off safety device from the flow pipe, it is
located near where the flow pipe exits from the heat exchanger.

Withdraw the retaining clip with the overheat cut-off safety
device from the lead plug.

Remove overheat cut-off safety device from clip and discard.

Fit new overheat cut-off safety device in clip and re-locate in the
lead plug, making sure that the terminals fully engage in the
plug.

Secure the new overheat cut-off safety device with the retaining
clip to the flow pipe in the same position as where the old one
was, see diagram 10.5.

Ensure that it is seated correctly on the flow pipe.

NOTE: Avoid hot areas when routing the overheat cut-off safety
device lead.

10.11 Insulation

Follow the relevant instructions in section 8 to remove the
controls assembly and burner.

Combustion Chamber Front

Remove the three burner securing screws to remove the
combustion chamber front cover from the controls assembly
and burner, see diagram 8.2.

Remove the combustion chamber front, then the front insulation
piece, see diagram 10.6.

Sides

Slide out the side insulation, see diagram 10.6.

Rear

With the side insulation pieces removed, lift out the rear insulation,
see diagram 10.6.

Note: Remove any debris that falls when the insulation has
been replaced.

When spare parts are required apply to your local supplier.

Diagram 10.5

10165

Advertising