Maintenance – Glow-worm Clearly Hybrid - Compact System User Manual

Page 34

Advertising
background image

0020096883_01 - 06/10 - Glow-worm

- 32 -

MAINTENANCE

Heating zones test

i

The heating zones can only be tested if you have
installed multiple zone valves.

• Using the buttons

,

select Zones on the screen.

• Press the button

to confi rm.

This menu is used to activate the 2 port
valve for each zone.

• Select the zone you want to test

using the buttons

.

• Press the button

to activate

the test.

• To disable the test, press the button

.

• Press the button

to confi rm.

DHW cylinder test

i

The domestic hot water cylinder test is only possible
if you have selected the domestic hot water cylinder
option.

• Using the buttons

,

select DHW cylinder on the screen.

• Press the button

to confi rm.

• Using the buttons

,

select DHW cylinder demand on
the screen.

• Press the button

to confi rm.

• Press the button

to activate

the test.

The domestic hot water cylinder 2-way
valve opens and the heat pump heats
the domestic hot water cylinder circuit.

• To disable the test, press the button

.

16.2.2 Aftersales

information

This menu provides access to Aftersales Service information.

• Using the buttons

,

select Parameters on the screen.

• Press the button

to confi rm.

• Using the buttons

, select

After sales info

on the screen.

• Press the button

to confi rm.

You can view or edit the following
information:

- date of last access to installer

menus,

- the name of the company which

provides the after sales service if
entered,

- the telephone number of the

company which provides the after
sales service if entered.