Installation, 8 electrical connections, 9 commissioning – Glow-worm Clearly Hybrid - Compact Hydraulic Module HB User Manual

Page 11: 10 specific adjustment

Advertising
background image

0020096881_02 - 08/10 - Glow-worm

- 9 -

INSTALLATION

8 Electrical connections

e

Incorrect installation can cause electric shock or

appliance damage. The electrical connection of

the appliance must be made only by a qualified

engineer.

The external wiring must be earthed, with correct polarity and in

accordance with current standards.

The manufacturer declines any responsibility for damages to

persons or others caused by the incorrect installation of the

appliance earthing. This includes failure to comply with current

standards.

NTC1

REL1

A

A

B

1

2

1

3

4

3

Key

1 Pump cable

2 Pump cable gland

3 Heating flow thermistor cable

4 Heating flow thermistor cable gland

Component

Voltage (cable section)

Pump

230 V (3 x 0.75 mm ²)

Thermistor

3.3 V (2 x 0.34 mm ²)

• Pass the pump cable (1) through the gland (2).

• Connect the cable (1) to the REL1 terminal in the Systempro.

• Tighten the gland (2).

• Pass the thermistor cable (3) through the gland (4).

• Connect the cable (3) to the NTC1 terminal in the Systempro.

• Tighten the gland (4).

9 Commissioning

• Refer to the system’s installation manual in order to activate

the installation.

Pump flow / pressure curve

60
50

40
30

20

10

0

300

600

900

1200

B

2

1

Key

1 Speed 2

2 Speed 3 (factory setting)

A Available pressure (kPa)

b flow in the circuit (l / h)

i

Speed 1 is not applicable to this system.

10 Specific adjustment

• Refer to the system’s installation manual to adjust the

installation.

Advertising