14 replacement of parts – Glow-worm cxi and Gas Valve User Manual

Page 50

Advertising
background image

50

0020013349-02

Diagram 14.28

230V CONTROLS
INTERFACE BOARD

USER INTERFACE

RETAINING
SCREW

11419

14 Replacement of Parts

Diagram 14.27

USER INTERFACE

SECURING SCREWS

11417

14.42 Control Box

For access, refer to section 14.43.

Remove relevant plugs and connectors, refer to wiring diagram
13.1.

Withdraw grommets and leads so they are hanging loose.

Unthread the retaining cord and remove the control box by
drawing it outwards away from its retaining slots, see diagram
14.26.

14.43 Fuse, Main PCB - Control Box

For access, refer to section 14.43.

The fuse is located at bottom right hand side of the PCB, see
diagram 13.1 or 14.26.

14.44 User Interface

Refer to section 14.38 for access.

Remove electrical plug.

Remove the securing screws, see diagram 14.27.

Withdraw the board.

When replacing the board refer to instructions supplied with
replacement PCB on setting it up.

14.45 230V Controls Interface

For access, refer to section 14.38.

Disconnect the electrical connection from the 230V controls
interface board and the electrical connection from the Main
PCB.

Remove the 230V controls interface retaining screw.

Remove the 230V controls interface board, see diagram 14.28.

14.46 Condense Drain

For access, refer to section 14.1.

Refer to diagram 14.29.

Remove the clips securing the flexible tubes to the siphon
adapter by twisting the clips slightly to disengage the clip jaws
from each other.

Remove black flexible tubes from siphon adapter.

Lift off the siphon adapter.

Diagram 14.26

9808

REAR PANEL

TORX
SCREWS (3)

CONTROL BOX

PCB RETAINING
CLIPS

RETAINING
CORD

RETAINING
SLOTS

12411

FUSE

MAIN PCB

Advertising