Fitting the analogue timer (to a boiler with timer

housing)

If the boiler already contains the timer housing, this

must be removed before fitting the timer accessory.

Remove front casing and hinge down control box.

Remove the timer housing and timer harness from the boiler.

Attach the harness supplied with the timer accessory to the PCB.

Locate the timer kit body into the space left by the previous timer timer

housing.

Plug the two harnesses together.

Ensure good positioning then replace the control box and front casing.

Re-establish mains and gas supply to the boiler.

Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT

Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.

3

Timer - Instructions for the User

3.1

Setting the time

Rotate the outer 24hr clock dial and align the arrow to the current time.

Setting the programme “ON and OFF” times.

OFF

(Tappets to

the inside)

ON

(Tappets to

the outside)

24hr

Clock

Dial

Selector

Switch

Arrow

(indicates

current time)

3

2

1

24

23

22

21

20

17

4

5

6

7

8

9

19

18

16

15

14

13

12

11

10

I

0

Select the ON times by pushing the black tappets to the

outside.

Select the OFF times by pushing the black tappets to

the inside.

Position the selector switch to the middle position

.

The heating will now operate at your chosen programme.

3.2

To override the timer

Move the selector switch to the I position and the

heating will operate continuously.

Move the selector switch to the 0 position to switch the

heating OFF.