4 installation – Glow-worm Hideaway 100CF User Manual

Page 10

Advertising
background image

10

221757A

Fit the distributor tube, see diagram 4.2 or 4.4 for location, see
diagram 4.3 for alignment. Fit appropriate fittings and plugs into
the boiler connections.

IMPORTANT. Do not route any pipe across the front of the
boiler thermostat pocket, the controls, burner supply pipe,
combustion chamber cover or the flueway cleaning door. The
gas supply pipe should be run along the left hand side of the
boiler. Pipework must not be routed directly below the draught
diverter hood across the boiler, but it may be routed under the
edges of the draught diverter.

When suitable installation clearances are available, position
the boiler in readiness to connect pipework.

If suitable clearances are not available it will be necessary to
preplumb the gas and water connections before positioning the
boiler.

When the front connections are used it is essential that any
pipework or fittings be assembled as shown in diagram 4.6, that
is, do not stick out more than shown.

Make the water connections to the system pipework.

Make the gas connection to gas supply at the union gas service
cock. Test the complete gas installation for soundness and
purge in accordance with the current issue of BS6891.

4.7 Pump within Boiler Casing

If the pump is to be fitted inside the boiler casing connect it as
shown to either of the upper front flow connections, see diagram
4.7.

There must be sufficient clearance “X” between the pump body
and the flueway cleaning door to allow removal of the door.

Dependent upon the type of pump used, the flow pipe
arrangements and pump may require titling backwards to clear
the casing door.

4.8 Flue Connection

The flue should be 125mm (5in) nominal diameter, refer to
Section 3 and diagram 1.1.

Fix and seal the flue to the hood in accordance with normal
practice.

Diagram 4.7

Diagram 4.4

WATER CONNECTIONS FULLY
PUMPED SYSTEMS

PUMP CLEARANCES

1310

ALTERNATIVE
FLOW POSITIONS
(Must be adjacent to
THERMOSTAT
PHIAL POCKET)

ALTERNATIVE
RETURN
POSITIONS
With distributor
tube (not shown)

Clearance 'X' must be left to enable cleaning
door removal and boiler servicing

'X'

FLUEWAY
CLEANING
DOOR

ALTERNATIVE
R.H. FLOW
CONNECTION

ISOLATING
VALVES

L.H. FLOW
CONNECTION

175
(7)

35 (1

3

/

8

)

0875

Diagram 4.6

PIPEWORK
CASING CLEARANCES

VIEW ON ARROW 'A'

1524

'A'

57 MAX.

(2

1

/

4

in.)

BOILER

57 MAX.
(2

1

/

4

in.)

4 Installation

Diagram 4.5

SECURING THE
THERMOSTAT PHIAL

1870

LOCATION
WASHER

PHIAL
POCKET

RETAINING
SPLIT PIN

THERMOSTAT
CAPILLARY