To Connect an Electrical Plug

The standard colours of three core flexible cable are,

Brown - live, Blue - neutral, Green and Yellow - earth.

As the markings on your plug may not correspond with these
colours, continue as follows:

The Blue cable must be connected to the terminal marked “N”
or “Black”.

The Brown cable must be connected to the terminal marked “L”
or “Red”.

The Green and yellow cable must be connected to the terminal

marked “E” or “Green” or the earth symbol

.

To Light the Boiler

WARNING. If the pilot light goes out for any reason, do not
attempt to relight until 3 minutes have elapsed.

Remove the door by pulling forwards with the fascia at the top.
Lift up to disengage from the bottom side lugs.

Refer to diagram 1 to identify controls.

Check that the mains electrical supply to the boiler is switched
OFF.

Push in slightly and turn gas control knob “A” clockwise until
is against its setting point.

Turn thermostat control knob “B” anticlockwise until “O” is
against its setting point.

Push in slightly and turn gas control knob “A” anticlockwise until

is against its setting point, then depress fully and hold in.

Push in and release piezo ignition button “C” until the pilot
burner lights.

Air may be present in the supply pipe so the lighting of the pilot
may need to be repeated until all the air has been expelled.

When the pilot is alight, view through window “E”, keep gas
control knob “A” fully pushed in for about 15 seconds, then
release.

If the burner fails to stay alight, wait 3 minutes, then repeat the
lighting procedure only now keep control knob “A” pushed in for
a little longer before releasing.

Press in and turn gas control knob “A” anticlockwise until

is

against its setting point.

If the gas control knob “A” is turned to

a safety lock prevents

it being turned on again for a short period. No attempt should
be made to relight the pilot until 3 minutes have elapsed.

Make sure that the pilot is alight and stable then switch on the
electrical supply.

Set any system controls to “ON” or “HIGH”.

Turn the boiler thermostat knob “B” clockwise until “MAX” is
against its setting point and the main burner will light. Adjust
thermostat to required setting between “MIN” and “MAX”.
“MAX” is about 82

o

C (180

o

F).

Refit the door by locating the hooked runner at the bottom into
the slot in the side panels and pushing onto the studs.

To Turn the Boiler Off

For short periods, turn the boiler thermostat control knob “B”
anticlockwise to “O”. The pilot will stay alight. To relight the
main burner turn thermostat control knob “B” clockwise to the
desired setting between “MIN” and “MAX”.

For longer periods, depress slightly and turn gas control knob
“A” fully clockwise until

is against its setting point. Turn

thermostat control knob “B” anticlockwise to “O”. Isolate the
boiler from the electrical supply. Follow full lighting procedure
to relight. Refer also to “Protection Against Freezing”.

Gas Leak or Fault

If a gas leak fault exists or is suspected the boiler must be turned
off, including the electrical supply and must not be used until the
fault has been put right. Advice/help should be obtained from
the local gas undertaking or your installation/servicing company.

Protection Against Freezing

If the boiler is to be out of use for any period of time during severe
weather conditions we recommend the whole system including
the boiler, be drained off to avoid the risk of freezing up. If an
immersion heater is fitted to the hot water cylinder make sure it
is switched off.

Sheet Metal Parts

WARNING. This boiler contains metal parts (components) and
care should be taken when handling and cleaning, with particular
regard to edges.

Cleaning

Keep the casing clean by wiping it occasionally with a damp
soapy cloth and dry with a polishing cloth.

Do not use abrasive cleaners.

Replacement Parts/Boiler Identification

If replacement parts are required apply to your local supplier.
Please quote the name of the boiler and its serial number which
can be found on the data label, positioned on the boiler top, to
the rear of the inclined flueway cleaning door.

Clearances

Minimum clearances must be left around the boiler as shown in
diagrams 1.3, 1.4 & 1.5.