10 replacement of parts – Glow-worm Micron 80FF User Manual

Page 27

Advertising
background image

27

2000225230C

Diagram 10.5

FRONT INSULATION

7195

RETAINING

SCREW

10 Replacement of Parts

ELECTRICAL

CONNECTIONS

RED AIR TUBE

CLEAR AIR
TUBE

SECURING

SCREW

FAN

SECURING

SCREW (3)

Diagram 10.7

7165

Diagram 10.6

RED AIR TUBE

ELECTRICAL

CONNECTIONS

CLEAR AIR

TUBE

SECURING

SCREW (2)

AIR

PRESSURE
SWITCH

7227

FAN

ASSEMBLY

IMPORTANT:

REMOVE ELECTRICAL CONNECTIONS
BY GRIPPING THE BOOT ONLY

SIDE INSULATION

12276

REAR INSULATION

SIDE INSULATION

10.11 Air Pressure Switch, Part No. 227053

- diagram 10.6

Gain Access as Section 5.2.

Remove the air pressure tubes and electrical connections from
the switch, release the screw and remove the switch.

When fitting the replacement make sure that the plastic tubes
are fitted as shown in diagram 10.6 and the electrical connections
as shown in diagram 9.5

10.12 Fan, Part No. 227035 - diagram 10.7

Refer to Section 5.3.

Remove the electrical connections and disconnect the air
tubes.

NOTE: Remove the electrical connections by pulling insulation
boots only.

Remove the fan assembly securing screw at the front, then
withdraw the assembly.

The fan is secured to the flue hood by three screws.

The polarity of the electrical connections are not important.

Advertising