1 general data, Sheet metal parts, 1 statutory requirements – Glow-worm Ultimate 50CF User Manual

Page 5: 3 range rating, 4 bsi certification, 5 gas supply, 2 data

Advertising
background image

5

221787B

1 General Data

1 General Notes and Information

This boiler is for use on natural gas G20.

Wherever possible, all materials, appliances and components
to be used shall comply with the requirements of applicable
British Standards.

Where no British Standard exists, materials and equipment
should be fit for their purpose and of suitable quality and
workmanship.

This boiler is not suitable for use out of doors.

Sheet Metal Parts

WARNING. When installing or servicing the boiler care should
be taken when handling sheet metal parts, to avoid any possibility
of personal injury.

1.1 Statutory Requirements

The installation of the boiler must be carried out by a competent
person in accordance with the relevant requirements of the
current issue of:

Manufacturer’s instructions, supplied.

The Gas Safety (Installation and Use) Regulations,

The Building Regulations, Local Water Company Byelaws, The
Building Standards (Scotland) Regulations (applicable in
Scotland), The Health and Safety at Work Act, Control of
Substances Hazardous to Health, The Electricity at Work
Regulations and any applicable local regulations.

Detailed recommendations are contained in the current issue of
the following British Standards and Codes of Practice:

BS6798, BS5440 Parts 1 and 2, BS5546 Part 1, BS5449,
BS6891, BS7478, BS7593, BS7671.

Manufacturer’s instructions must not be taken as overriding
statutory requirements.

1.3 Range Rating

The boiler is range rated and may be adjusted to suit the
individual system requirements.

The respective Table 1 gives the ratings and settings.

A

B

C

D

E

F

H

K

L

M

N

R

S

764

328

168

213

149

56

39

115

741

480

640

345

23

MODEL

Diagram 1.1

GENERAL DIMENSIONS (all dimensions in mm)

50CF

0020M

B

D

C

H

F

A

R

L

N

GAS CONNECTION RC

1

/

2

(

1

/

2

in. BSPT)

WATER CONNECTION RC1 (1in. BSPT)

M

K

E

S

CL

CL

FLUE

INSIDE DIAMETER
OF SOCKET FOR
100mm (4in)
NOMINAL
DIAMETER FLUE

0020M

1.4 BSI Certification

The boiler is certificated to the current issue of BS6332 Part 1,
invoking the current issue of BS5258 Part 1 for performance
and safety. It is, therefore, important that no alteration is made
to the boiler without permission, in writing, from Hepworth
Heating Ltd.

Any alteration that is not approved by Hepworth Heating Ltd.,
could invalidate the BSI Certification of the boiler, warranty and
could also infringe the current issue of the Statutory
Requirements.

1.5 Gas Supply

The gas installation shall be in accordance with the current
issue of BS6891.

The supply from the governed meter must be of adequate size
to provide a steady inlet working pressure of 20mbar (8in wg) at
the boiler.

DATA
LABEL

6.4 litres

(1.4 gal)

WATER
CONTENT

60.0 kg

(132.0lb)

WEIGHT (approx)

230V~50Hz, fused 3A

ELECTRICITY
SUPPLY

Rc1

WATER
CONNECTION

Rc

1

/

2

GAS
CONNECTION

On right hand side of electrical

control box

1.2 DATA