9 fault finding – Glow-worm Ultimate 80FF User Manual

Page 26

Advertising
background image

26

2000225233B

Diagram 9.1

9 Fault Finding

NEON
INDICATORS

Neon Indicators - An Aid to Fault Finding

THE NEON INDICATORS ARE AN AID TO FAULT FINDING ONLY. FAILURE OF ANY OF THE NEON INDICATORS DOES NOT

WARRANT THE REPLACEMENT OF AN OTHERWISE SATISFACTORY PRINTED CIRCUIT BOARD (PCB).

Fault with mains supply or PCB fuse

Ignition, pilot or flame proving fault -
see detailed fault finding chart.

Air flow proving fault - that is fan or air
pressure switch - see detailed fault finding
chart.

NO

NO

NO

Overheat cut off device tripped or
thermostat, overheat cut off device faulty
- see detailed fault finding chart.

Is neon 2 lit?

Is neon 4 lit?

System satisfactory

Is neon 3 lit?

Is main burner operating?

Is neon 1 lit?

NO

NO

YES

YES

YES

YES

YES

Multi-functional control/harness problem
- see detailed fault finding chart.

4120

9.1 Electrical

IMPORTANT: On completion of the Service/Fault Finding task
which has required the breaking and remaking of the electrical
connections the earth continuity, polarity, short circuit and
resistance to earth checks must be repeated using a suitable
multimeter.

Refer to neon indicators “An Aid to Fault Finding” diagram 9.1,
Boiler Fault Finding diagram 9.2, Pump Overrun Fault Finding
diagram 9.3, the Functional Flow diagram 9.4 , and the Pictorial
Wiring diagram 9.5.

9.2 Electrical Supply Failure

Failure of the electrical supply will cause the burner to go out.

Operation will normally resume on restoration of the electrical
supply. If the burner does not relight after an electrical supply
failure the overheat device may need resetting.

Remove the control cover, see diagram 6.6 and push the rest
button on the front of the control box, see diagram 6.1.

If the cutoff operates at any other time press the rest button and
the burner should relight. If the fault persists refer to fault finding
chart.

NOTE: The pump may run for several minutes when power is
first applied, regardless of call for heat.