GoDEX MX30i User Manual

Page 24

Advertising
background image

20

3

Setting and Control for Operation Panel

3.4 Label Calibration and Self Test

Label Calibration

The printer can automatically detect and store label height.
That means the host computer does not need to transmit the label height to the printer.

Self Test

Self-test function lets you check whether the printer is functioning normally.
Here is how you run the label size calibration and self test.
1. Check that the label stock is loaded correctly.
2. Turn off the printer and pressing the FEED button.
3. Turn on the printer again, while pressing the FEED button. After waiting for the buzzer sounds twice,
the printer will now measure the label stock and store the label height.
4. Once the printer has successfully calibrated the label stock, it will print a self-test label.
The contents of a self-test printout are listed below.

Model & Version

USB ID setting

Serial port setting

Port status

(The default value is 1, which means that all ports open)

Number of forms

Number of graphics

Number of fonts

Number of Asian fonts

Number of Databases

Number of Scalable fonts

Free memory size

Speed, Density, Ref. Point, Print direction

Label width, Form length, Stop position

Cutter, Label Dispenser, Mode

Sensor Setting

Code Page

MX30i:VX.XXX
USB S/N:12345678
Serial port:96,N,8,1
PORT State L S E U B
1 1 1 1 1
#####################
0000 FORM(S) IN MEMORY
0000 GRAPHIC(S) IN MEMORY
000 FONT(S) IN MEMORY
000 ASIAN FONT(S) IN MEMORY
000 DATABASE(S) IN MEMORY
000 TTF(S) IN MEMORY
16616 KB FREE MEMORY
^S2 ^H19 ^R000 ~R200 ~Q+0
^W72 ^Q50,3 ^E10
Option:^D0 ^O0 ^AD
See:0.9 1.1 1.0[0.2_14]
Code Page:850