Getting Started

Turn off the computer’s power before connecting the scanner, then

power up the computer once the scanner is fully connected.

Connecting the Scanner

USB:

Keyboard Wedge:

Reading Techniques

Recall Defaults

The following bar code resets all standard product default settings.

Interface Selections
USB

Keyboard Wedge

³

9

9

9

9

9

8

Recall Defaults

³

3 1 6 4 0 0

USB Keyboard

Emulation

³

5 1 5 5 1 4 3

Keyboard Wedge Emulation

Prefix

Scan one of the following bar codes to program your scanner to add

or remove a start of text character, or AIM or Nixdorf identification

characters before each bar code.

³

1

1

6

6

1

5

³

1

1

6

6

0

5

³

1

0

7

9

0

5

STX Prefix On

STX Prefix Off

³

1

0

7

9

1

5

AIM ID Prefix On

AIM ID Prefix Off

Suffix

Scan one of the following bar codes to program your scanner to add

or remove a carriage return, line feed, tab, or end of text after each

bar code.

³

1

1

6

6

1

3

³

1

1

6

6

0

3

³

1

1

6

6

0

4

CR Suffix On

CR Suffix Off

³

1

1

6

6

1

2

LF Suffix On

³

1

1

6

6

0

2

LF Suffix Off

³

1

1

6

6

1

0

Tab Suffix On

³

1

1

6

6

0

0

Tab Suffix Off

³

1

1

6

6

1

4

ETX Suffix On

ETX Suffix Off

User Configurable Prefix/Suffix

One or two prefix or suffix characters can be added and assigned for

data transmission. Use one of the codes below with a 3 code byte

sequence that represents the desired character (see

ASCII

Conversion Chart

, end of document) for your prefix or suffix. (To add

additional prefix/suffix characters, refer to your Single-Line

Configuration Guide.)
Scan the

Enter/Exit Programming bar code to begin. Then scan

the 3 digit decimal equivalent of the ASCII character into the

appropriate character location with the code byte bar codes (see

Code Bytes

, end of document). To save, scan the

Enter/Exit

Programming bar code again.
Example: To add an asterisk (*) as a prefix, scan the bar codes:
1. Enter/Exit Programming

2. Configurable Prefix #1

3. Code Byte 0

4. Code Byte 4

5. Code Byte 2

6. Enter/Exit Programming

³

9

0

4

5

0

0

Configurable Suffix #1

³

9

0

4

6

0

0

Configurable Suffix #2

³

9

0

3

5

0

0

Configurable Prefix #1

³

9

0

3

6

0

0

Configurable Prefix #2

³

9

9

9

9

9

9

Enter/Exit Programming

Supplements

Scan one of the bar codes below to program your scanner for 2 or 5

digit bar code supplements.

977 (2 Digit) Supplement Required: Turn on this feature when a 2

digit supplement is required for EAN-13 codes that begin with 977.

Scan Modes

³

1

0

1

2

1

7

2 Digit Supplements

On

³

1

0

1

2

0

7

2 Digit Supplements Off

³

1

0

1

2

1

6

5 Digit Supplements

On

³

1

0

1

2

0

6

5 Digit Supplements Off

³

1

0

1

3

1

4

977 Supplements On

³

1

0

1

3

0

4

977 Supplements Off

UPC/EAN Formatting

Scan

Convert UPC-A to EAN-13 and a leading zero is transmitted

before a UPC-A bar code to convert it to EAN-13.

Scan

Transmit Lead Zero on UPC-E to transmit a zero before each

UPC-E bar code.

³ 4 1 8 3 3 4

Continuous Blinky_1

³

1

0

7

5

1

4

Convert UPC-A to

EAN-13

³

1

0

7

5

0

4

Don’t Convert UPC-A to

EAN-13

³

1

0

7

5

1

3

Transmit Lead Zero on

UPC-E

³

1

0

7

5

0

3

Don’t Transmit Lead

Zero on UPC-E

GS220

Bar Code Scanner

Quick Start Guide

220-QS Rev D

12/12

8 1 8 9 0 0

Continuous Blinky_2

1 1 8 7 0 3

Continuous Blinky_3

Recall Defaults

³

9

9

9

9

9

8

When you scan

Continuous Blinky Scan mode, the scanner beam

flashes and scans continuously. To enter the

mode, scan below codes:

1. Enter/Exit Programming 2. Continuous Blinky_1
3. Continuous Blinky_2 4. Continuous Blinky_3
5. Enter/Exit Programming

To exit from

Continuous Blinky Scan mode, scan the Recall

Defaults barcode.