2 preset save and recall functions, 3 power functions, 4 special commands – Hall Research HSM-I-04-04 User Manual

Page 14: User’s manual 12

Advertising
background image

User’s Manual

12

Command:

COn,m<cr> stands for Connect Output n to input m

Response:

COn,m<cr>

Variations:

Command:

COn <cr> stands for Connect Output n Query

Response:

COn,m<cr>

Command:

CO*,m<cr> stands for Connect All Outputs to input m

Response:

CO1,m<cr>

CO2,m<cr>

CO3,m<cr> (for 4x4 matrices only)

CO4,m<cr> (for 4x4 matrices only)

4.2 Preset Save and Recall Functions


Command:

PRx<cr> stands for Preset Recall. x = preset 1~ 8

Response:

CO1, m

1

<cr>

CO2, m

2

<cr>

CO3, m

3

<cr> (for 4x4 matrices only)

CO4, m

4

<cr> (for 4x4 matrices only)

Command:

PSx<cr> stands for Preset Save. x = preset 1~ 8

Response:

None (the current tie pattern is saved in EEPROM)


4.3 Power Functions


Command:

PW1<cr> stands for Power On

Response:

PW1<space><cr>

CO1, m

1

<cr>

CO2, m

2

<cr>

CO3, m

3

<cr> (Only for 4x4 matrices)

CO4, m

4

<cr> (Only for 4x4 matrices)

Important Note on Power ON Command

This command can take up to 10 seconds to complete. Upon powering up the unit will recall

the previous state of each output prior to powering off and restore each connection.

Command:

PW0<cr> stands for Power Off

Response:

PW0<cr>

Variation:

Command:

PW<cr> stands for Power Query

Response:

PWx<cr><lf> x=0 (off), or 1 (on)


4.4 Special Commands


Command:

FB<cr> stands for Firmware Boot

Response:

Depends on power state when the command was issued. This command is

equivalent to unplugging the power supply and reconnecting it.