3 power functions, 4 factory defaults, Genesis digital™ hdmi matrix switches – Hall Research HSM-I-08-08 User Manual
Page 17

Genesis Digital™ HDMI Matrix Switches
15
CV6,m<cr>
CV7,m<cr>
CV8,m<cr>
CA1,m<cr>
CA2,m<cr>
CA3,m<cr>
CA4,m<cr>
CA5,m<cr>
CA6,m<cr>
CA7,m<cr>
CA8,m<cr>
Command:
PSx<cr> stands for Preset Save (where x = preset 1~ 8)
Response:
PSx<cr>
4.3 Power Functions
Command:
PW1<cr> stands for Power On (where m = input [1-8])
Response:
PW1<cr>
CV1,m<cr>
CV2,m<cr>
CV3,m<cr>
CV4,m<cr>
CV5,m<cr>
CV6,m<cr>
CV7,m<cr>
CV8,m<cr>
CA1,m<cr>
CA2,m<cr>
CA3,m<cr>
CA4,m<cr>
CA5,m<cr>
CA6,m<cr>
CA7,m<cr>
CA8,m<cr>
Important Note on Power ON Command
This command can take up to 6 seconds to complete. Upon powering up the unit will recall the
previous state of each output prior to powering off and restore each connection.
Command:
PW0<cr> stands for Power Off
Response:
PW0<cr>
Query:
Command:
PW<cr> stands for Power Query
Response:
PWx<cr> x=0 (off), or 1 (on)
4.4 Factory Defaults
Command:
FD<cr> stands for Factory Defaults
Response:
FD<cr>